Photoelectric
Reflex Switches
With the photoelectric
reflex switches (e.g. WL 24-2), the emitted light beam is reflected by a
reflector and then recieved and evaluated by the device. |
V
12 VL 12
Ambient temperature -25°C
+70°C
Connection type cable / connector
Dimensions (W x H x D in mm) 12 x 66 / 80
Protection category 67
Range (mm) 50 ... 2500
Supply voltage DC 10
30 V
Switching outputs PNP, open collector: Q
Type of light infra-red light
Remarks Flat optics for flush fitting
Robust
metal housing
Dark-switching
Cable
or plug connection
Reverse
polarity and short circuit protection
|
|
|
V
18 Angle VL 18 Angle
Ambient temperature -25°C
+60 / 70°C
Connection type cable / connector socket
Dimensions (W x H x D in mm) 18 x 74 / 86
Protection category 67
Range (m) 2
Supply voltage DC 10
30 V
Switching outputs PNP Q
Type of housing plastic / metal
Type of light red light / infra-red light |
W
12-2 WL 12-2
Ambient temperature -25 °C
+60 °C
Connection type cable / connector socket
Dimensions (W x H x D in mm) 15 x 49 x 41.5
Protection category 67
Recommended operating range (m) / onto reflector 0
5 / PL 80 A
Supply voltage DC 10
30 V
Switching outputs NPN / PNP, Q+Q
Type of housing metal
Type of light red light / polarising filter
Typical maximum range (m) / onto reflector 7 / PL 80 A
|
|
|
W
140 WL 140
Accessories Cable receptacles, mounting brackets,
reflectors
Ambient temperature -25° ... +55 °C (Operation), -40° ...
+ 70 °C (Storage)
Connection type Cable/PlugM 8, 3-/4-pin
Dimensions (W x H x D in mm) 11 x 41.8 x 20
Output current (mA) max. 100 mA
Protection category 67
Range (m) 0.01 ... 6
Recommended operating range (m) / onto reflector 0.01 ... 5/PL 80 A
Supply voltage 10 ... 30 V DC
Switching outputs PNP/NPN
Type of light Red light
Typical maximum range (m) / onto reflector 0.01 ... 6/PL 80 A
Remarks Photoelectric reflex switch, light spot diameter 3 mm at 100 mm
distance
Fast response time
Also suitable for Diamond Grade reflecting tape
Adjustable
sensitivity
LED indicator: function reserve
|
W
150 WL 150
Accessories reflectors
Ambient temperature -25 °C ... +55 °C
Connection type cable / connector socket M8
Dimensions (W x H x D in mm) 10 x 28 x 17.5
Protection category 67
Recommended operating range (m) / onto reflector 0,005...2,4/ PL 80A
Supply voltage DC 10 ... 30 V
Switching outputs NPN / PNP
Type of housing synthetic material
Type of light red light /polarising filter
Typical maximum range (m) / onto reflector 0,005...2,8 / PL 80 A
|
|
|
W
160 WL 160
Ambient temperature -25 °C
+55 °C
Connection type cable / connector socket
Dimensions (W x H x D in mm) 11 x 23 x 38 / 11 x 38 x 23
Pollution signal output / test input yes / yes
Protection category 67
Recommended operating range (m) / onto reflector 0
2,5 auf reflector
P 250
Supply voltage DC 10
30 V
Switching outputs PNP / NPN
Type of light red light/ polarising filter
Typical maximum range (m) / onto reflector 0
2.5 onto reflector
P 250
Remarks Horizontal and vertical models
Polarisation
filter for detection of object with reflective surfaces
|
W
160T WL 160T red light
Accessories Reflectors
Ambient temperature -25...+55° C (Operation), -40...+70° C (Storage)
Connection type Cable; Plug M 8, 3-/4 pin
Dimensions (W x H x D in mm) 11 x 47.5 x 23
Output current (mA) max. 100
Protection category 67
Supply voltage 10...30 V DC
Type of light Red light
Typical maximum range (m) / onto reflector 0.01...1/P 250 (included)
Remarks Focussed retro reflexive proximity switch, spot diameter 3 mm at
100 mm scanning distance
Fast response time
Detection of smallest objects
Detection of (semi-) transparent objects
LED indicator: function reserve |
|
|
W
170 WL 170
Ambient temperature -25 °C
+55 °C
Connection type cable / connector socket M 8
Dimensions (W x H x D in mm) 12 x 37 x 28.6
Protection category 67
Recommended operating range (m) / onto reflector 0.01
3.1 / 0.,1
0.56 / P250
Supply voltage DC 10
30 V
Switching outputs NPN / PNP
Type of housing synthetic material
Type of light red light, visible / polarising filter : yes/no
Remarks Polarising filter enabling reliable deteftion of objects with
shiny surfaces
Also
suitable for ´Diamond Grade´ reflective tape
Visible
red light LED transmitter as alignment aid
|
W
18-2 WL 18-2
Ambient temperature -40°C
+60°C
Connection type cable (2 m / 5 m) / connector socket
Dimensions (W x H x D in mm) 17 x 75 x 32.5
Protection category 67
Recommended operating range (m) / onto reflector 4.5 / PL 80 A
Supply voltage DC 10
30 V
Switching outputs NPN / PNP, Q+Q
Type of light red light / polarising filter
Typical maximum range (m) / onto reflector 7.0 / PL 80 A
Remarks Insensitive to ambient light sources (HF lamps, flashing alarm
lamps)
No
mutual interference if devices are installed opposite each other
Operating
temperature -40 °C...+ 60 °C
Fast
response time
|
|
|
W
24 Exi WL 24 Exi
Ambient temperature -25°C
+50°C
Connection type terminal chamber / connector socket
Dimensions (W x H x D in mm) 27 x 87.6 x 65
Protection category 67
Recommended operating range (m) / onto reflector 0
8 / PL 80 A
Supply voltage DC 8.2 V (5.0
13.5 V)
Switching outputs according to Namur, DIN 19234
Type of light red light / polarising filter
Typical maximum range (m) / onto reflector 15.5 / PL 80 A
Remarks Red light
Explosion
protection EEx ia IIC T6
Plug rotatable by 90°
Terminal
chamber
|
W
250 WL 250
Ambient temperature -25°C
+55°C
Connection type cable / M12 device plug
Dimensions (W x H x D in mm) 20 x 60 / 65 x 43
Protection category 67
Recommended operating range (m) / onto reflector 0.01
8 / P 250
Supply voltage DC 10
30 V / DC 12
240 V / AC 24
240
V
Switching outputs NPN /PNP / Rel. 1xu
Type of light red light / polarising filter
Typical maximum range (m) / onto reflector 9.5 / P 250
Remarks Polarisation filter, ensuring reliable detection of objects with
reflective surfaces
Robust, compact plastic housing
Adjustable sensitivity setting (2 turns) with position indicator (270°)
M
12 plug rotatable by 90°
|
|
|
W
260 WL 260
Ambient temperature -25°C
+55°C
Connection type terminal chamber / M12 device plug
Dimensions (W x H x D in mm) 25 x 77.5 x 63
Protection category 67
Recommended operating range (m) / onto reflector 0.01
5 / P 250
Supply voltage DC 10
30 V / DC 12
240 V / AC 24
240 V
Switching outputs NPN / PNP / Rel. 1xu
Type of light red light / polarising filter
Typical maximum range (m) / onto reflector 0.01
14/ PL 80 A
Remarks Polarising filter providing reliable detection even of objects
with reflective surfaces
Adjustable
sensitivity
Terminal
chamber or M 12, 4-pin plug
Test input
|
W
27-2 WL 27-2
Ambient temperature -40°C
+60°C
Connection type cable / connector socket
Dimensions (W x H x D in mm) 24.6 x 80 x 53.5
Protection category 67 / 65
Recommended operating range (m) / onto reflector 0
10 / PL 80 A
Supply voltage DC 10
30 V / UC 24
240 V (+10%, -20%) /DC
26,5 V ... 31,6 V
Switching outputs NPN / PNP / Q+Q / Rel.1xu
Type of light red light / polarising filter
Typical maximum range (m) / onto reflector 14 / PL 80 A
Remarks Visible red light
Front
screen heating, optional
With
integrated ASI chip
|
|
|
W
34 WL 34
Accessories Mounting brackets, reflectors
Ambient temperature -40 °C...+60 ° C
Connection type M 16-screw fixing/Plug
Dimensions (W x H x D in mm) 27 x 92 x 70
Housing material ABS
Pollution signal output / test input yes/yes
Protection category 67
Recommended operating range (m) / onto reflector 0...15/PL 80 A
Supply voltage 10...30 V DC, 12...240 V DC, 24...240 V AC
Switching outputs NPN/PNP/relay 1 x u
Type of light Red light, polarizing filter
Typical maximum range (m) / onto reflector 22/PL 80 A
Remarks Sturdy plastic housing (ABS)
Large operating reserve in visible red light
Easy accessible terminal chamber
M
16-screw fixing and plug rotatable by 90°
Selectable
time delay, optional
|
W
36 WL 36
Ambient temperature -40°C
+55°C
Connection type terminal chamber / connector socket
Dimensions (W x H x D in mm) 36 x 85 x 72
Protection category 67 / 65
Range (m) 22
Recommended operating range (m) / onto reflector 0.1
15 / PL 80
A
Supply voltage DC 10
30 V / UC 24
240 V
Switching outputs NPN / PNP / Q+Q / Rel.1xu
Type of light red light / polarising filter
Typical maximum range (m) / onto reflector 23 / PL 80 A
Remarks Robust plastic housing
Visible
red light
Selectable
time delay
|
|
|
W
4-2 WL 4-2
Ambient temperature -25 °C ... +55 °C
Connection type cable / connector socket
Dimensions (W x H x D in mm) 16 x 32 x 12
Protection category 67
Recommended operating range (m) / onto reflector 0 ... 1,7 / PL 80 A
Supply voltage DC 10 ... 30 V
Switching outputs NPN / PNP
Type of housing synthetic material
Type of light red light / polarising filter
Typical maximum range (m) / onto reflector 0 ... 2,8 / PL 80 A
Remarks Insensitive to ambient light sources
Reliable
operation if devices are installed opposite each other
Permissible
operating temperature -40 °C...+ 60 °C
Rapid
response time
|
W
45 WL 45
Ambient temperature -25°C
+55°C
Connection type terminal chamber
Dimensions (W x H x D in mm) 60 x 105 x 105
Pollution signal output / test input VMA, TE
Protection category 67 / 65
Recommended operating range (m) / onto reflector 0 ...28 / 4 x PL 80 A;
1
45 / OP 60
Supply voltage DC 10
60 V / UC 24
240 V (+10%, -25%)
Switching outputs NPN / PNP / Q+Q / Rel.1xu
Type of light red light / polarising filter
Typical maximum range (m) / onto reflector 1 ... 55 / OP 60
Remarks Robust metal housing
Red
light
Adjustable
sensitivity
Font
lens heating, optional
|
|
|
W
9 WL 9
Ambient temperature -25 °C
+55 °C
Connection type cable / connector socket
Dimensions (W x H x D in mm) 13 x 63 x 22
Pollution signal output / test input -/yes
Protection category 67
Recommended operating range (m) / onto reflector 0
2.5 / PL 80
A
Supply voltage DC 10
30 V
Switching outputs NPN / PNP, Q+Q
Type of housing synthetic material
Type of light red light / polarising filter
Typical maximum range (m) / onto reflector 3.5 / PL 80 A
|